====High Temp Thermistor====
====High Temp Thermistor====
You need to calculate the Steinhart-Hart coefficient and ß values using a [https://www.thinksrs.com/downloads/programs/therm%20calc/ntccalibrator/ntccalculator.html tool]
You need to calculate the Steinhart-Hart coefficient and ß values using a [https://www.thinksrs.com/downloads/programs/therm%20calc/ntccalibrator/ntccalculator.html tool] and the data from the [https://docs.google.com/spreadsheets/d/e/2PACX-1vQ5LGUbs4B3uAqrQeEvOqFw1ZFCB3qpAPk3ThCYK9mBS7uiTEF4hjOD6-znxU25MZo19cjhfqDsc06Y/pubhtml Slice Engineering RT Tables]


Plug them to RepRap via
Plug them to RepRap via


<code>M308 S1 P"temp1" Y"thermistor" T500000 B3571.97 R2500 C1.196220e-7</code>
<code>M308 S1 P"temp1" Y"thermistor" T500000 B3571.97 R2500 C1.196220e-7</code>

Latest revision as of 22:05, 21 June 2020

High Temp Thermistor

You need to calculate the Steinhart-Hart coefficient and ß values using a tool and the data from the Slice Engineering RT Tables

Plug them to RepRap via

M308 S1 P"temp1" Y"thermistor" T500000 B3571.97 R2500 C1.196220e-7